Fire-rated coated rectangular ductwork

Fire Rated Ducts

Life-Safety Critical Products: Our fire rated ducts are manufactured in compliance with BS 476 Part 24 (UK) and UL 555S (USA) standards. They are designed to maintain structural integrity and prevent smoke migration during fire events, protecting evacuation routes in buildings up to 2–4 hours.

Product Features

  • Fire integrity ratings: E30, E60, E90, E120 & E240 (up to 4 hours)
  • Manufactured from galvanised steel with mineral wool / calcium silicate boards
  • Pressure class: Low, Medium and High — up to ±2000 Pa
  • Tested to BS 476 Part 24 and UL 555S standards
  • Internal and external insulation options available
  • Suitable for smoke extract, pressurisation and general ventilation systems
  • Factory-made to SMACNA and DW 144 dimensional tolerances
  • Bespoke fittings, damper pockets and inspection access doors available

Technical Specifications

ParameterSpecification
MaterialGalvanised Steel (GI) + Mineral Wool / Calcium Silicate
Steel Thickness0.6 mm to 1.6 mm (as per duct size)
Fire RatingE30 / E60 / E90 / E120 / E240
Pressure ClassLow (≤500 Pa) / Medium (≤1000 Pa) / High (≤2000 Pa)
Temperature ResistanceUp to 400°C (smoke extract applications)
StandardsBS 476 Part 24, UL 555S, SMACNA, DW 144
Sizes100 mm × 100 mm up to 3000 mm × 1500 mm
Surface FinishBare GI or with intumescent coating

Applications

Hospitals & Healthcare

Operating theatres, critical care units and escape corridors requiring validated fire compartmentalisation.

Airports & Metro Stations

Underground passenger areas and tunnels where smoke control is a primary life-safety requirement.

Commercial High-Rise Buildings

Smoke extract shafts, pressurised stairwells and escape corridors in multi-storey developments.

Industrial & Data Centres

Process areas with fire suppression systems where duct integrity during suppression is critical.

Flanged Ducts

Flanged ducts are used in high-pressure HVAC systems and industrial air-handling applications where standard duct joints cannot maintain pressure class. Shree Venus manufactures TDC (Transverse Duct Connection) and raw-flange systems to SMACNA and DW 144 specifications.

Flange Types Available

  • TDC / TDF Flanges: Transverse duct connectors with snap-lock corner pieces, suitable for medium-pressure systems
  • Angle Iron Flanges: Welded mild steel flanges for heavy-duty and high-pressure applications
  • Slip & Drive: For low-pressure applications with quick installation
  • Raw-flange (turned & bolted): For industrial process ventilation requiring maximum seal integrity
SMACNA Certified DW 144 Compliant BS 476 Part 24 UL 555S ISO 9001:2015 Made in India

All fire rated ducts are third-party tested and certified. We provide full test certificates, material traceability documents and installation guides with every supply. Our technical team assists with fire compartmentalisation drawings and on-site supervision.

Answers

Frequently asked questions

What standard do fire rated ducts follow in India?
In India, fire-rated ducts must comply with BS 476 Part 20 and Part 22 (UK), or UL 555S (USA). Shree Venus fire rated ducts are tested and certified to these international standards, making them acceptable across Indian projects requiring fire-rated HVAC ductwork.
What fire rating duration is available?
Shree Venus supplies fire-rated ducts with 60-minute (E60) and 120-minute (E120) fire integrity ratings as per BS 476. The appropriate rating is selected based on the fire compartmentation requirement of the building.
Which industries require fire-rated ducts?
Fire-rated ducts are mandatory in hospitals, pharmaceutical plants, data centres, airports, malls, high-rise residential, and any building where fire compartmentation of the HVAC system is required by local fire codes.

Delivery

Made in Chennai, shipped across India

Shree Venus Energy System Pvt Ltd manufactures HVAC ductwork, stainless steel ducts, PUF insulation, fire-rated ducts, acoustic panels and cold room panels and doors, and ships to project sites anywhere in India. Four plants keep production close to our five strongest markets, and each of those states is covered end to end — not just its capital.

Tamil Nadu

Served state-wide, direct from Sriperumbudur and Hosur

Karnataka

Served state-wide from Hosur, on the Karnataka border

Telangana

Served state-wide from our Choutuppal plant

Andhra Pradesh

Served state-wide from Choutuppal and Sriperumbudur

Kerala

Served state-wide from Sriperumbudur and Hosur

Outside these five states we quote and ship nationwide — freight is arranged from whichever plant is nearest your site.

4 plants — Chennai · Sriperumbudur · Hyderabad · Hosur +91 94440 59655 info@shreevenus.com

5,000+

Projects completed

1,000+

Clients served

30+

Years in HVAC

4

Manufacturing plants

Related products

Ready to price your project?

Send a GA drawing, BOQ or a simple sketch — our engineers revert with a detailed quotation within two business hours.

WhatsApp us